How To Determine The Operating Condition Of A Copper Wire Granulator Bearing?
Mar 06, 2026
I. Listen to the sound: Identify abnormal noises. During normal operation, the bearing should emit a uniform, low-pitched "humming" or "whooshing" sound. The following sounds indicate a potential malfunction:
"Squeaking" sharp sound: Often indicates insufficient lubrication; dried grease causes metal-to-metal friction.
"Clicking" or "crunching" sound: May indicate peeling, indentations, or foreign object intrusion on the raceway or rolling element surface.
Periodic "hooking" sound: Indicates scratches, grooves, or corrosion on the inner and outer raceways.
"Clanging" discontinuous sound: May indicate cage cracks or severe lubrication problems.
"Clanging" knocking sound: Indicates excessive clearance between the sliding bearing and the shaft, or a loose rolling bearing.
It is recommended to use an electronic stethoscope or mechanical stethoscope to assist in diagnosis and improve accuracy.
II. Temperature Check: Sensing Abnormal Temperature Rise
Bearing temperature is a crucial indicator of lubrication and load conditions:
Under normal circumstances, the temperature tends to stabilize within 1-2 hours after startup;
The general operating temperature should not exceed 85℃. If it remains above 80℃ without a decreasing trend, the machine should be stopped immediately for inspection;
Common causes of excessively rapid temperature rise include: insufficient lubrication, excessive grease, improper installation, or excessive load.
A preliminary assessment can be made by lightly touching the bearing housing with the back of your hand. However, using an infrared thermometer for precise measurement is highly recommended.
III. Visual Inspection and Lubrication Condition
Visual inspection can reveal obvious physical damage and sealing problems:
Seal condition: Aging or cracked oil seals can lead to dust intrusion and accelerated wear;
Grease condition: If the grease is blackened, lumpy, emulsified (milky white), or contains metal particles, it indicates deterioration or contamination;
Bearing housing bolts: Loose bolts can cause increased vibration and affect operational stability;
End cap discoloration: A bluish-black or pale yellow discoloration indicates that the bearing has undergone high-temperature annealing, resulting in a decline in material properties.
IV. Vibration Measurement: Quantifying Operational Health
Vibration detection is one of the most sensitive early warning methods for faults:
Use a vibration meter to measure the vibration velocity of the bearing:
Small equipment: >2.8 mm/s - Warning;
Medium to large equipment: >4.5 mm/s - Requires close monitoring;
If the vibration value continues to rise or the spectrum analysis shows a match with the bearing's characteristic frequency, it indicates structural damage such as pitting or spalling.
Vibration is extremely sensitive to damage such as spalling, indentation, and cracks. It is recommended to record data regularly and establish a trend analysis archive.
V. Comprehensive Judgment Based on Operating Conditions
In the absence of specialized instruments, the following empirical standards can be used as a reference:
Check every 40 hours of operation; in high-dust or heavy-load environments, this should be shortened to 20–30 hours; New bearings should be closely monitored after the first 100 hours of operation to rule out abnormalities during the break-in period;
If abnormal noise and temperature rise do not improve after grease application, internal damage is highly likely, requiring disassembly and inspection for confirmation.